Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 141
Filtrar
1.
Braz. j. oral sci ; 22: e239389, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1509457

RESUMO

Aim: The purpose of this study was to investigate the biofilm effect on the hybrid ceramic-resin cement bond strength (BS) by comparing two methods. Methods: Teeth were distributed into groups (n=5), according to the resin cement (Maxcem Elite-(MC) or NX3 Nexus-(NX)) and degradation method (24h or 7 days in distilled water; 7 or 30 days incubated with biofilm and 30 days in sterile media). Treated surfaces of Vita Enamic blocks (5x6x7mm) were luted to treated or no treated dentin surfaces and light-cured. After 24h, beams were obtained (1x1x10mm) and stored accordingly. The flexural bond strength (FBS) was assessed by four-point bending test. Additional beams were obtained from new teeth (n=5), stored for 24h or 7 days in distilled water, and submitted to a microtensile bond strength (µTBS) assay. Failure modes were determined by scanning electron microscopy (100X). The flexure strength of the cements (n=10) was assessed by a four-point bending test. Data were analyzed by 1 and 2-ways ANOVA, and Tukey's test (α=0.05). Results: There was no significant difference between the degradation methods for the FBS groups. For the µTBS, the significant difference was as follows: NX 7days > NX 24h > MC 7days = MC 24h. Failure mode was mainly adhesive and mixed, but with an increase of cohesive within cement and pre-failures for the MC groups assessed by µTBS. NX had better performance than MC, regardless of the method. Conclusions: The biofilm had no effect on the materials BS and FBS test was a useful method to evaluate BS of materials with poor performance


Assuntos
Resistência à Tração , Microscopia Eletrônica de Varredura , Colagem Dentária , Biofilmes , Cimentos de Resina
2.
Restor Dent Endod ; 47(4): e45, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36518615

RESUMO

Objectives: This study evaluated the relationship between the battery charge level and irradiance of light-emitting diode (LED) light-curing units (LCUs) and how these variables influence the Vickers hardness number (VHN) of a bulk-fill resin. Materials and Methods: Four LCUs were evaluated: Radii Plus (SDI), Radii-cal (SDI), Elipar Deep Cure (Filtek Bulk Fill, 3M Oral Care), and Poly Wireless (Kavo Kerr). Irradiance was measured using a radiometer every ten 20-second activations until the battery was discharged. Disks (4 mm thick) of a bulk-fill resin (Filtek Bulk Fill, 3M Oral Care) were prepared, and the VHN was determined on the top and bottom surfaces when light-cured with the LCUs with battery levels at 100%, 50% and 10%. Data were analyzed by 2-way analysis of variance, the Tukey's test, and Pearson correlations (α = 5%). Results: Elipar Deep Cure and Poly Wireless showed significant differences between the irradiance when the battery was fully charged versus discharged (10% battery level). Significant differences in irradiance were detected among all LCUs, within each battery condition tested. Hardness ratios below 80% were obtained for Radii-cal (10% battery level) and for Poly Wireless (50% and 10% battery levels). The battery level showed moderate and strong, but non-significant, positive correlations with the VHN and irradiance. Conclusions: Although the irradiance was different among LCUs, it decreased in half of the devices along with a reduction in battery level. In addition, the composite resin effectiveness of curing, measured by the hardness ratio, was reduced when the LCUs' battery was discharged.

3.
Braz. j. oral sci ; 21: e225136, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354771

RESUMO

Aim: To evaluate the influence of cobalt-chromium (Co-Cr) coping fabrication methods and ceramic application on the marginal and internal fit of metal-ceramic crowns. Methods: Co-Cr copings for metal-ceramic crowns were prepared by lost wax casting or CAD-CAM machining of sintered blocks. The fit was analyzed using the silicone replica technique at four assessment points: marginal gap (MG), axial wall (AW), axio-occlusal (AO) angle, and central occlusal (CO) wall. After the initial analysis, the copings were ceramic-veneered with the layering technique, and the fit was again determined. Data were statistically analyzed by paired and unpaired Student's-t test (α=0.05). Results: Marginal and internal fit before ceramic application according to the coping manufacturing method showed significant differences only at CO (p < 0.001), with milled copings (137.98±16.71 µm) showing higher gap values than cast copings (112.86±8.57 µm). For cast copings, there were significant differences at MG (before 109.13±8.79 µm; after 102.78±7.18 µm) and CO (before 112.86±8.57 µm; after 104.07±10.63 µm) when comparing the fit before and after ceramic firing. For milled copings, there was significant difference only at AO (before 116.39±9.64 µm; after 108.54±9.26 µm). Conclusion: This study demonstrated that the coping fabrication method influenced the internal fit. Ceramic firing maintained or improved the fit of the metal-ceramic crowns. The marginal discrepancy of all restorations, before and after ceramic firing, can be considered clinically acceptable


Assuntos
Cerâmica , Ligas Metalo-Cerâmicas , Adaptação Marginal Dentária , Coroas
4.
Rev. Cient. CRO-RJ (Online) ; 7(1): 31-39, Jan-Apr 2022.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1382163

RESUMO

Objetivo: Avaliar o efeito de um protetor de superfície na sorção e solubilidade de cimentos de ionômero de vidro. Materiais e Métodos: Quatro materiais foram selecionados: ionômero modificado por resina encapsulado (Riva Light Cure); modificado por resina pó/líquido (Vitremer); convencional encapsulado (Equia Forte) e convencional pó/líquido (Fuji IX). Foram confeccionados 20 espécimes de cada, sendo metade com proteção superficial do Equia Forte Coat. As amostras foram mantidas em estufa a 37°C em repouso por 5 dias. Em seguida, esses foram pesados em intervalos de 24 horas. A espessura e o diâmetro foram medidos com um paquímetro digital para o cálculo do volume. Novas pesagens foram realizadas para a obtenção da massa intermediária. Em seguida, as amostras foram mantidas em repouso por 5 dias a 37°C e realizada nova pesagem. Resultados: Os dados obtidos de sorção e solubilidade foram submetidos à análise de variância (ANOVA dois fatores, material e protetor de superfície) e teste Tukey ( =0,05). Para sorção, houve diferença significativa apenas para o fator material (p<0,05), Vitremer > Equia Forte > Riva Light Cure > Fuji IX. O ionômero Fuji IX apresentou os menores valores de sorção, diferindo significativamente dos demais materiais, independentemente do uso do protetor superficial. Não houve diferença significativa para o fator proteção de superfície (p>0,05). Para solubilidade não houve diferença significativa no fator material, protetor de superfície ou interação material*protetor. Conclusão: O uso do protetor superficial não influenciou nos valores de sorção e solubilidade dos ionômeros avaliados e o ionômero convencional Fuji IX apresentou menores taxas de sorção.


Objective: evaluate the effect of a surface coating agents on the sorption and glass ionomer cements solubility. Materials and Methods: Four materials were selected: Encapsulated resin-modified ionomer (Riva Light Cure); Powder/liquid Encapsulated resin-modified (Vitremer); Encapsulated conventional (Equia Forte) and powder/ liquid conventional (Fuji IX). Twenty samples of each were made, half with surface protection of Equia Forte Coat. The samples were kept in an oven for 5 days. These were then weighed at 24-hour intervals. The thickness and diameter were measured using a digital caliper to calculate their volume. New weightings were performed to obtain the intermediate mass. Then, the samples were kept at rest for 5 days and weighed again. Results: The sorption and solubility data obtained were subjected to analysis of variance (two-way ANOVA, material and surface coating agents) and Tukey test ( =0.05). For sorption, there was a significant difference only for the material factor (p<0.05), Vitremer > Equia Forte > Riva Light Cure > Fuji IX. The Fuji IX ionomer showed the lowest sorption values, differing significantly from the other materials, regardless of the use of surface coating agents. There was no significant difference for the surface protection factor (p>0.05). For solubility there was no significant difference for the material factor, surface coating agents or material*surface coating agent interaction. Conclusion: The use of surface coating agents did not influence the sorption and solubility values of the evaluated ionomers and the conventional Fuji IX ionomer showed lower sorption rates.


Assuntos
Soluções/química , Materiais Dentários , Cimentos de Ionômeros de Vidro/química , Solubilidade , Teste de Materiais , Água , Absorção
5.
Restor Dent Endod ; 47(1): e7, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35284332

RESUMO

Objectives: This study evaluated the bleaching efficacy of different in-office protocols associated with violet light emitting diode (V-LED), and measured the pulpal temperature rise caused by V-LED with or without gel application. Materials and Methods: Bovine incisors were distributed in 4 groups (n = 10): VL - V-LED; HP - 35% hydrogen peroxide (control); HYB - hybrid protocol, V-LED applied without gel for 10 irradiation cycles followed by V-LED applied with gel for another 10 irradiation cycles; and HPVL - gel and V-LED applied for 20 irradiation cycles. Three bleaching sessions were performed with 7-day intervals. Bleaching efficacy was evaluated with Δ E a b * , ΔE 00 and ΔWID . Data were recorded at baseline, 7, 14, 21 and 70 days. For pulpal temperature rise, thermocouples were placed inside the pulp chamber of human incisors. To determine intrapulpal temperature, the teeth were irradiated with V-LED with or without application of bleaching gel. Color difference data were analyzed by 2-way repeated measures ANOVA and Tukey's test. Pulpal temperature was analyzed by t-test (α = 5%). Results: VL exhibited lower color ( Δ E a b * and ΔE 00) and whiteness changes (ΔWID ) than the other groups. HPVL presented higher color change values than HYB. HYB and HPVL showed not different ΔWID values; and HP showed the highest whiteness changes at all times. There were significant differences comparing ΔT with gel (8.9°C) and without gel application (7.2°C). Conclusions: HPLV was more efficient than HYB. The 2 protocols with VL showed similar results to control. Gel application combined with VL promoted higher pulpal temperature than to the no gel group.

6.
Am J Orthod Dentofacial Orthop ; 161(5): 638-651.e1, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35016812

RESUMO

INTRODUCTION: This study aimed to assess sagittal and vertical skeletal and dentoalveolar changes through the use of 3-dimensional imaging in prepubertal Class II malocclusion patients treated with a cantilever Herbst appliance (HA). Condyle-glenoid fossa positional changes were also quantified. METHODS: This retrospective cohort study assessed 22 children (11.2 years ± 1.2) consecutively treated with a cantilever HA for 12 months and 11 untreated children (aged 9.3 ± 0.30 years) that served as controls. Cone-beam computed tomography was performed at baseline (T1) and at the end of the observation period (T2). Movements in the regions of interest were measured as linear displacements from cone-beam computed tomography images through algebraic calculations. A Student t test for independent samples was used for group equivalence testing at T1, and the treatment differences between T2 and T1 were evaluated by 2 analyses of covariance, one considering the expected growth unit as a covariate and the other with an annualized factor. RESULTS: The largest dental movement was a mesial movement of mandibular molars (3.70 mm), whereas the largest skeletal changes consisted of a larger relative length of the mandible (difference of 1.2 mm) in the HA group than in the control group. CONCLUSIONS: Within the study limitations (retrospective cohort, historical control group, and sample size), 3-dimensional imaging suggests that HA corrected Class II malocclusion in a predominantly prepubertal sample through more dental than skeletal changes. The changes were more significant in the sagittal than in the vertical direction. In addition, relative stability in the condyle-fossa relationship was noted.


Assuntos
Má Oclusão Classe II de Angle , Aparelhos Ortodônticos Funcionais , Cefalometria , Criança , Humanos , Má Oclusão Classe II de Angle/diagnóstico por imagem , Má Oclusão Classe II de Angle/terapia , Mandíbula , Estudos Retrospectivos
7.
Clin Oral Investig ; 26(3): 2281-2297, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35031879

RESUMO

OBJECTIVES: A systematic review was performed to analyze the clinical performance of class I and II restorations in posterior teeth placed with the incremental or the bulk-filling techniques. The primary outcome was retention/fracture rate, and the secondary outcomes evaluated were anatomical form, surface texture, color match, marginal adaption, marginal discoloration, caries, and postoperative sensitivity. METHODS: Electronic and manual searches were performed for randomized clinical trials comparing the clinical performance of composite resin restorations in posterior teeth placed with the incremental or the bulk-filling techniques. The Cochrane Collaboration risk of bias tool was used to assess the quality of the studies and the GRADE tool was used to access the quality of the evidence. RESULTS: Fourteen studies were included in this systematic review and most of them had unclear risk of bias. The risk difference (RD) for retention/fracture was 0.00 (95%CI = - 0.01, 0.01; p = 0.86) for 1-1.5 years of follow-up; 0.00 (95%CI = - 0.02, 0.02; p = 0.88) for 2-3 years of follow-up; 0.05 (95%CI = - 0.08, 0.18; p = 0.46) for 5 or more years of follow-up. The RD for postoperative sensitivity was 0.04 (95%CI = - 0.02, 0.10; p = 0.18) for up to 30 days; 0.00 (95%CI = - 0.01, 0.02; p = 0.63) for 1-1.5 years of follow-up; and 0.00 (95%CI = - 0.01, 0.02; p = 0.71) for 2-3 years of follow-up. For the other secondary outcomes, no significant differences were observed (p > 0.05) between the restorative techniques. The certainty of evidence was graded as moderate. CONCLUSIONS: The clinical performance of class I and II restorations in posterior teeth is similar when placed with the incremental and bulk-filling techniques. CLINICAL RELEVANCE: Based on the results of this study, posterior restorations placed with bulk-filling technique present satisfactory clinical performance, which is similar to direct restorations placed with the conventional incremental technique, considering various follow-up periods evaluated. TRIAL REGISTRATION:  CRD42018108450.


Assuntos
Resinas Compostas , Cárie Dentária , Resinas Compostas/uso terapêutico , Cárie Dentária/tratamento farmacológico , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Humanos
8.
Odontology ; 110(1): 99-105, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34279762

RESUMO

The pretreatment of dentin with cross-linking agents during bonding procedures has been proposed to improve the mechanical properties of the collagen in the hybrid layer and reduce the biodegradation of the adhesive interface. The aim of this study was to evaluate the influence of pretreatment with two carbodiimides on the dentin bond strength of universal adhesives, after thermocycling. Three universal adhesives in the self-etching mode were used (Single Bond Universal-SBU, Clearfil Universal-CLU and Ambar Universal-ABU). A self-etching adhesive system (Clearfil SE Bond-CSB) was used as control. Two carbodiimides, 1-ethyl-3-(3'-dimethylaminopropyl)-carbodiimide (EDC) and N,N'-dicyclohexylcarbodiimide (DCC), were applied for 1 min. The excess solution was removed with absorbent paper and the universal adhesives were applied. The specimens were stored for 24 h in distilled water at 37 °C or 10,000 thermal cycles (5-55 °C, 30 s) and then were prepared for microtensile bond strength test (n = 4 teeth, average of 21 sticks per group). Data were analyzed using three-way ANOVA and Tukey's (α = 5%). After 24 h, SBU and CSB had statistically similar bond strength values for the control groups (22.07 ± 9.03 and 19.82 ± 7.28 MPa), with EDC (30.21 ± 11.30 and 19.67 ± 5.36 MPa) and DCC (30.12 ± 13.43 and 19.82 ± 7.28 MPa) pretreatments (p > 0.05). The use of EDC (32.57 ± 9.60 MPa) and DCC (24.71 ± 9.87 MPa) showed statistically higher bond strength for CLU than for the control group (14.62 ± 6.16 MPa; p < 0.05). After thermocycling, the SBU, CLU, and CSB groups showed statistically similar bond strengths with the use of EDC (27.08 ± 8.44; 18.74 ± 5.41; and 24.55 ± 10.43 MPa) and without the use of cross linkers (20.06 ± 7.99; 22.55 ± 9.04; and 26.54 ± 10.13 MPa; p > 0.05). Groups tested after 24 h in distilled water presented higher bond strength than those submitted to thermocycling. It can be concluded that the use of cross linkers influenced the immediate bond strength of the universal adhesives, and this was dependent on the combination of the adhesive system and type of carbodiimide. The use of EDC increased the immediate bond strength of CLU. DCC increased the bond strength of ABU at 24 h, but the values were lower than those of the control group after aging for three out of the four adhesives.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Carbodi-Imidas , Resinas Compostas , Cimentos Dentários , Dentina , Teste de Materiais , Cimentos de Resina , Resistência à Tração
9.
Braz. dent. sci ; 25(1): 1-9, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1361885

RESUMO

Objetivo: O objetivo foi avaliar a resistência de união de seis adesivos experimentais contendo sistemas fotoiniciadores binários ou ternários, associados a três diferentes concentrações de MDP (0-12% em peso) após 12 meses de armazenamento em água destilada. Material e Métodos: Adesivos experimentais foram preparados com: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT e etanol, contendo sistemas fotoiniciadores binários (CQ/amina) ou ternários (CQ/amina/DPIHFP ­ 0,5% em peso). Foi adicionado a esta composição 0%, 6% ou 12% em peso de MDP. Os sistemas adesivos foram aplicados seguindo o protocolo com condicionamento ácido. Moldes cilíndricos transparentes foram colocados sobre a dentina hibridizada, preenchidos com resina composta e fotopolimerizados. Os corpos-de-prova foram armazenados em água destilada a 37oC por 24h ou 12 meses e submetidos ao ensaio de microcisalhamento (n=6). Os dados foram analisados por ANOVA de três fatores e teste de Tukey (α=5%). Resultados: Para o sistema binário, após 12 meses de armazenamento, todos os valores de resistência de união foram semelhantes. Em relação à degradação da resistência de adesão ao longo do tempo, as formulações de MDP de 6% e 12% mostraram resistência de união mais estável do que 0% de MDP. Para o sistema ternário, todas as formulações (0%, 6% e 12% em massa de MDP) mostraram resistência de união estável em função do tempo. Conclusão: Para o sistema binário, as concentrações de 6 e 12% em massa de MDP foram capazes de manter a resistência de união em função do tempo, enquanto que para o sistema ternário, a estabilidade de união foi obtida independentemente da concentração de MDP. Pode-se concluir que, para a formulação dos adesivos utilizados neste estudo, independente do sistema fotoiniciador, a concentração de 12% MDP apresentou valores de resistência de união mais estáveis após 12 meses de armazenamento em água (AU)


Objective: The aim was to evaluate the bond strength of six experimental adhesives containing binary or ternary photoinitiator systems, associated with three different MDP concentrations (0-12wt%) after 12 months of storage in distilled water. Material and Methods: Experimental adhesives were prepared with: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT, and ethanol, containing binary (CQ/amine) or ternary (CQ/amine/DPIHFP (diphenyliodonium hexafluorophosphate) ­ 0.5wt%) photoinitiator systems. It was added to this composition 0wt%, 6wt%, or 12wt% of MDP. The adhesive systems were applied following the etch-and-rinse protocol. Transparent cylindrical molds were placed on the hybridized dentin, filled with composite resin and light-cured. The specimens were stored in distilled water at 37oC for 24h or 12 months and submitted to a microshear bond strength test (n=6). Data were analyzed by three-way ANOVA and Tukey's test (α=5%). Results: For the binary system, after 12 months of storage, all bond strength values were similar. Regarding bond strength degradation over time, 6wt% and 12wt% MDP formulations showed more stable bond strength than 0wt% MDP. For the ternary system, all formulations (0wt%, 6wt% and 12wt%) showed stable bond strength over time. Conclusion: For the binary photoinitiator system, the 6wt% and 12wt% MDP concentrations were able to keep bond strength stable over time, while for the ternary system, bond strength stability was achieved regardless the MDP concentration. (AU)


Assuntos
Cimentos Dentários , Fotoiniciadores Dentários
11.
Angle Orthod ; 90(4): 571-577, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33378491

RESUMO

OBJECTIVE: To evaluate the esthetic perceptions of orthodontists and laypersons for facial profile changes after orthodontic treatment using Herbst or Forsus appliances. MATERIALS AND METHODS: Pre- and posttreatment facial profile contour images of 20 Class II patients treated with Herbst (group H; n = 10) and Forsus (group F; n = 10) appliances were analyzed by 30 orthodontists and 30 laypersons, who graded them from 1 (unattractive) to 10 (very attractive) using a visual analog scale. Two assessments were carried out with a 15 day-interval. In the first evaluation, 40 images were presented in a random sequence. In the second evaluation, initial and final facial profile images of each patient were randomly presented side by side. To compare groups in relation to treatment method, Mann-Whitney tests were used. To evaluate differences between time points, Wilcoxon tests were used. RESULTS: In the first evaluation, there was a significant difference between initial and final images only for group H, for both laypersons (P = .017) and orthodontists (P = .037). There was also a significant difference between laypersons and orthodontists in their ratings of posttreatment Herbst appliance profiles (P = .028). There was no significant difference between initial and final facial profile images for group F and no significant differences between or within evaluator groups in their ratings of initial or final Forsus appliance profiles. In the second evaluation, there was a significant difference between appliance groups only for laypersons, who considered cases treated with the Herbst appliance more attractive than those treated with the Forsus (P = .031). Laypersons also considered Herbst profiles more attractive than did orthodontists (P = .047). CONCLUSIONS: Class II malocclusion treatment using the Herbst appliance may produce a more esthetically improved facial profile silhouette compared with Forsus appliances. The magnitude of perceived changes may not be considered clinically relevant.


Assuntos
Má Oclusão Classe II de Angle , Aparelhos Ortodônticos Funcionais , Cefalometria , Estética , Humanos , Má Oclusão Classe II de Angle/diagnóstico por imagem , Má Oclusão Classe II de Angle/terapia , Percepção , Resultado do Tratamento
12.
Restor Dent Endod ; 45(4): e49, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33294414

RESUMO

OBJECTIVES: The aim of this study was to perform a clinical and radiographic analysis of endodontically treated teeth (ETT) restored with cast metal posts (CMPs) or prefabricated glass fiber posts (GFPs) and crowns. MATERIALS AND METHODS: Fifty ETT were restored with 25 CMPs and 25 GFPs at a private dental clinic between 2001 and 2016. The restorations consisted of 12 all-ceramic crowns, 31 metal-ceramic crowns, and 7 composite resin crowns. Demographic data, type of teeth, type of post-and-core system, time of placement, crown restorations, the number of proximal contacts, the type of antagonist, and reports of any complications after post-and-core placement were recorded for each patient. Assessments were performed at baseline (radiographic) and follow-up (radiographic and clinical). Data were analyzed by the McNemar test, the Pearson χ2 test, and Kaplan-Meier survival curves (α = 0.05). The mean follow-up was 67.6 months. RESULTS: No significant difference was observed for any of the radiographic parameters when the baseline and final radiographs were compared. In the clinical evaluation, anatomical form (p = 0.009) and occlusion (p = 0.001) showed significant differences according to the type of crown restoration; specifically, metal-ceramic and all-ceramic crowns outperformed composite resin crowns. CONCLUSIONS: CMPs and GFPs showed favorable results for restoring ETT after 6 years of follow-up. All-ceramic and metal-ceramic crowns showed higher survival rates and better clinical outcomes.

13.
J. oral res. (Impresa) ; 9(5): 405-413, oct. 31, 2020. ilus, graf, tab
Artigo em Inglês | LILACS | ID: biblio-1179032

RESUMO

Introduction: This study evaluated the influence of sonic vibration and thermocycling on the bond strength of fiberglass posts using conventional dual-cured and self-adhesive resin cements. Material and Methods: Ninety-six single-rooted endodontically treated teeth were divided randomly into eight groups according to the cement used (dual-cured or self-adhesive resin cement), use of sonic vibration during post accommodation, and aging conditions (24h in distilled water or 5,000 thermal cycles). The fiberglass posts (White Post DC1, FGM) were cleaned with alcohol, treated with silane and cemented with dual-cured (Allcem Core, FGM) or with self-adhesive resin cement (seT, SDI). For groups in which sonic vibration was used, the posts were accommodated, and sonic vibration was applied for 10 s using a special tip placed on top of the post (Sonic Smart Device, FGM). Pull-out tests were performed after storage in distilled water for 24h at 37°C or after thermocycling (5000 cycles, at 5°C and 55°C). The results were evaluated using three-way ANOVA and Tukey's test (α=0.05). Results: Significant differences were not observed between the bond strengths of dual-cured (87.93±41.81 N) and self-adhesive cement (82.53±41.43 N). Bond strength for the sonic vibration groups (100.36±42.35 N) was significantly higher than for groups without sonic vibration (70.13±34.90 N). There were significant differences between specimens subjected to thermocycling (98.33±39.42 N) and those stored for 24h in distilled water (72.16±39.67 N). Conclusion: It can be concluded that both sonic vibration and thermocycling significantly improved bond strength of fiberglass posts with the two evaluated resin cements.


Introducción: Este estudio evaluó la influencia de la vibración sónica y el termociclado en la fuerza de unión de los postes de fibra de vidrio utilizando cementos de resina autoadhesivos y de curado dual convencionales Material y Métodos: Se dividieron aleatoriamente noventa y seis dientes tratados endodónticamente de raíz única en ocho grupos según el cemento utilizado (cemento de resina de curado dual o autoadhesivo), el uso de vibración sónica durante la acomodación posterior y las condiciones de envejecimiento (24 horas agua destilada o 5.000 ciclos térmicos). Los postes de fibra de vidrio (White Post DC1, FGM) se limpiaron con alcohol, se trataron con silano y se cementaron con cemento de curado dual (Allcem Core, FGM) o con cemento de resina autoadhesivo (seT, SDI). Para los grupos en los que se utilizó vibración sónica, se acomodaron los postes y se aplicó la vibración sónica durante 10 s utilizando una punta especial colocada en la parte superior del poste (Sonic Smart Device, FGM). Las pruebas de extracción se realizaron después del almacenamiento en agua destilada durante 24 horas a 37ºC o después del termociclado (5000 ciclos, a 5ºC y 55ºC). Los resultados se evaluaron mediante ANOVA de tres vías y la prueba de Tukey (α = 0.05). Resultados: No se observaron diferencias significativas entre las resistencias de adhesión del cemento de curado dual (87,93 ± 41,81 N) y el cemento autoadhesivo (82,53 ± 41,43 N). La fuerza de unión para los grupos de vibración sónica (100,36 ± 42,35 N) fue significativamente mayor que para los grupos sin vibración sónica (70,13 ± 34,90 N). Hubo diferencias significativas entre los especímenes sometidos a termociclado (98,33 ± 39,42 N) y los almacenados durante 24 h en agua destilada (72,16 ± 39,67 N). Conclusión: Se puede concluir que tanto la vibración sónica como el termociclado mejoraron significativamente la fuerza de unión de los postes de fibra de vidrio con los dos cementos de resina evaluados.


Assuntos
Humanos , Vibração , Técnica para Retentor Intrarradicular/instrumentação , Cimentos de Resina/química , Resistência à Flexão , Vidro , Sonicação/métodos , Raiz Dentária , Colagem Dentária , Adesivos Dentinários , Dentina/química , Ondas Ultrassônicas
14.
J Clin Exp Dent ; 12(7): e644-e649, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32905070

RESUMO

BACKGROUND: To evaluate the bleaching efficacy of at-home carbamide peroxide (CP) gels in two concentrations, containing or not a desensitizing agent. MATERIAL AND METHODS: Forty incisors were divided into four groups (n=10), according to gel concentrations (10% or 22%), and presence or not of 3% potassium nitrate in the gel. A thin layer of gel was applied to the buccal surface of each tooth for 2h/day for 4 weeks. Bleaching efficacy was measured using a spectrophotometer, and ∆E*ab, ∆E00 and ∆WID were calculated. Measurements were performed at baseline, 7, 14, 21, 28, and 35 days following the first gel application. Data were analyzed by two-way RM-ANOVA and Tukey's test (α=0.05). RESULTS: Regarding gel concentration or potassium nitrate inclusion, both gels resulted in color change above the perceptibility thresholds, which were similar between gels. Regarding time, significant differences were observed between color change values at 7 days and other time periods. ∆WID ranged from 3.8 to 9.6. Significant moderate to strong positive correlation was observed among the parameters. CONCLUSIONS: Nor the CP concentration, neither the inclusion of potassium nitrate in the gel, had influence on bleaching efficacy. All gels were effective and showed good results from the first weeks' application. Key words:Tooth bleaching, carbamide peroxide, desensitizer, potassium nitrate, color.

15.
Braz Oral Res ; 34: e105, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32876118

RESUMO

The aim of this research was to evaluate the influence of MDP (10-methacryloyloxydecyl dihydrogen phosphate) concentration and application mode of experimental adhesives on microshear bond strength (µSBS) to dentin after storage in distilled water at 37°C for 24h and 6 months. Five experimental adhesives were prepared with: CQ, DABE, BHT, ethanol, HEMA, TEGDMA, Bis-EMA, UDMA, and Bis-GMA. Concentrations of 0 wt%, 3 wt%, 9 wt%, 12 wt% or 15 wt% of MDP were added to their composition. The adhesives were applied to flat dentin surfaces in etch-and-rinse or self-etching modes. Cylindrical molds filled with light-cured composite resin were placed above the dentin. The specimens were stored in distilled water at 37oC for 24h or 6 months and submitted to µSBS testing. The adhesives were also submitted to pH analysis. The data were analyzed by one-way ANOVA, three-way ANOVA and Tukey's test (α = 5%). All the adhesives used in the etch-and-rinse mode showed significantly higher bond strength than the adhesives applied in the self-etching approach. The 9 wt% adhesive showed the highest bond strength values, and 3 wt% was most stable after storage. A strong negative correlation between MDP concentration and pH was observed. It was concluded that the formulations with low concentrations of MDP (up to 9 wt%) showed better results for bond strength and bond strength degradation over time.


Assuntos
Colagem Dentária , Adesividade , Resinas Compostas , Cimentos Dentários , Dentina , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência à Tração
16.
Braz Dent J ; 31(3): 264-271, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32667515

RESUMO

The objective of this work was to evaluate the effects of in vitro and in situ biodegradation on the surface characteristics of two resin cements and a hybrid ceramic system. One hundred and eighty specimens (4X1.5mm) of each material (Maxcem Elite, NX3 Nexus and Vita Enamic) were made and randomly distributed in twelve groups (n=15) according to the material and biodegradation method. The specimens were then submitted to the following challenges: storage in distilled water 37 ºC for 24 h or 7 days, storage for 7 days, at 37 ºC, in stimulated saliva or in situ. The in situ stage corresponded to the preparation of 15 intraoral palatal devices, used for 7 days. Each device presented 3 niches, where a sample of each materials was accommodated. Specimens from both saliva and in situ groups suffered a cariogenic challenge, corresponding to the application of a solution of 20% of sucrose, 10 times throughout each day. After each biodegradation method, the surface roughness (Ra), Vickers hardness (VHN) and scanning electron microscopy (SEM) analyzes were performed. The data collected were evaluated by Levene test, two-way ANOVA and Tukey`s test (α=5%). The in situ challenge promoted the greater biodegradation, regardless of the material. Regarding the materials, the Vita Enamic VHN was negatively affected by all biodegradation methods and the Nexus NX3 presented better performance than the self-adhesive cement tested. Therefore, within the conditions of this work, it was concluded that in situ biodegradation can affect negatively the surface characteristics of indirect restorative materials.


Assuntos
Materiais Dentários , Cimentos de Resina , Cerâmica , Dureza , Teste de Materiais , Propriedades de Superfície
17.
Braz. dent. j ; 31(3): 264-271, May-June 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132298

RESUMO

Abstract The objective of this work was to evaluate the effects of in vitro and in situ biodegradation on the surface characteristics of two resin cements and a hybrid ceramic system. One hundred and eighty specimens (4X1.5mm) of each material (Maxcem Elite, NX3 Nexus and Vita Enamic) were made and randomly distributed in twelve groups (n=15) according to the material and biodegradation method. The specimens were then submitted to the following challenges: storage in distilled water 37 ºC for 24 h or 7 days, storage for 7 days, at 37 ºC, in stimulated saliva or in situ. The in situ stage corresponded to the preparation of 15 intraoral palatal devices, used for 7 days. Each device presented 3 niches, where a sample of each materials was accommodated. Specimens from both saliva and in situ groups suffered a cariogenic challenge, corresponding to the application of a solution of 20% of sucrose, 10 times throughout each day. After each biodegradation method, the surface roughness (Ra), Vickers hardness (VHN) and scanning electron microscopy (SEM) analyzes were performed. The data collected were evaluated by Levene test, two-way ANOVA and Tukey`s test (α=5%). The in situ challenge promoted the greater biodegradation, regardless of the material. Regarding the materials, the Vita Enamic VHN was negatively affected by all biodegradation methods and the Nexus NX3 presented better performance than the self-adhesive cement tested. Therefore, within the conditions of this work, it was concluded that in situ biodegradation can affect negatively the surface characteristics of indirect restorative materials.


Resumo O objetivo deste trabalho foi avaliar os efeitos da biodegradação in vitro e in situ nas características superficiais de dois cimentos resinosos e de um sistema cerâmico híbrido. Cento e oitenta espécimes (4X1,5mm) de cada material (Maxcem Elite, NX3 Nexus e Vita Enamic) foram distribuídos aleatoriamente em doze grupos (n=15) de acordo com o material e o método de biodegradação. Os espécimes foram então submetidos aos seguintes desafios: armazenamento em água destilada 37ºC por 24 horas ou 7 dias, armazenamento por 7 dias, a 37ºC, em saliva estimulada ou in situ. O estágio in situ correspondeu à preparação de 15 dispositivos intra-orais palatinos, utilizados por 7 dias. Cada dispositivo apresentou 3 nichos, onde uma amostra de cada material foi acomodada. As amostras dos grupos saliva e in situ sofreram um desafio cariogênico, correspondendo à aplicação de uma solução de 20% de sacarose, 10 vezes ao longo de cada dia. Após cada método de biodegradação, foram realizadas as análises de rugosidade superficial (Ra), dureza Vickers (VHN) e microscopia eletrônica de varredura (MEV). Os dados coletados foram analisados por meio do teste de Levene, ANOVA two-way e teste de Tukey (α=5%). O desafio in situ promoveu maior degradação, independentemente do material. Em relação aos materiais, a VHN do Vita Enamic foi afetada negativamente por todos os métodos de degradação e o Nexus NX3 apresentou melhor desempenho que o cimento autoadesivo testado. Portanto, dentro das condições deste trabalho, concluiu-se que a biodegradação in situ pode afetar negativamente as características superficiais de materiais restauradores indiretos.


Assuntos
Cimentos de Resina , Materiais Dentários , Propriedades de Superfície , Teste de Materiais , Cerâmica , Dureza
18.
Braz Dent J ; 31(1): 69-77, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32159709

RESUMO

The objective was to evaluate the color stability of ceramic veneers luted with resin cements and pre-heated composite resins (60oC) for 12 months, and determine the degree of conversion (DC) of the luting agents. Two resin cements (AllCem Veneer, light-cured (LRC) and AllCem, dual-cured (DRC)] and three composite resins [Z100 (MNCR-minifilled), Herculite Classic (MHCR-micro-hybrid) and Durafill (MCCR-microfilled)] were used for cementing 0.8-mm-thick lithium-silicate glass-ceramic laminates (Suprinity, shade B2-HT, Vita) on bovine enamel (n=10). The specimens were stored at 37oC in distilled water. CIELab parameters were determined at 24h after luting (baseline), 7, 30, 90, 180 days and 12 months. Three specimens were prepared for DC evaluation, performed by micro-Raman spectroscopy. Data were analyzed by ANOVA and Tukey's test (a=5%). For ΔEab and ΔE00, there were significant differences for luting material (p<0.001), time (p<0.001), and double interaction (p<0.001). The groups cemented with MHCR (1 year), MCCR (90 days and 1 year) and MCCR-PH (1 year) were the ones with ΔE values greater than the acceptability threshold. All other groups maintained their ΔE lower than the acceptability threshold after 1 year in distilled water. Regarding DC, there were no significant differences (p=0.127) among the materials. Non-significant negative correlations were observed between the mean ΔEab and DC (R=-0.65) and ΔE00 and DC (R=-0.64). A significant positive correlation was observed mean ΔEab and ΔE00 (R=0.99). It was concluded that the different luting agents influenced the final color of the restorations. The heating of the composite resins did not affect their DC.


Assuntos
Cerâmica , Cimentos de Resina , Animais , Bovinos , Cor , Resinas Compostas , Porcelana Dentária , Facetas Dentárias , Seguimentos , Teste de Materiais
19.
Ceram Int ; 46(16 Pt A): 26168-26175, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33716378

RESUMO

The objective of this study is to investigate the magnitude of structural degradation of a monolithic translucent zirconia caused by clinically relevant grinding and polishing procedures, when associated or not with low temperature degradation (LTD), induced by accelerated hydrothermal aging using autoclave or thermocycling Ninety disks (Ø12 × 1 mm) were prepared from dental zirconia for monolithic restorations (Vipi Block Zirconn Translucent, Vipi). The specimens were divided into 3 groups (n = 30) according to surface treatment: As Sintered (untreated), Grind (diamond bur), Grind + Polish (diamond bur + polish); and then subdivided according to aging method (n = 10): Baseline (no aging), Autoclave (134°C, 2.2 kgf/cm2 pressure for 5 h), and Thermocycling (200,000 cycles, 5°C and 55°C, for 15 s each). Roughness, biaxial flexural strength and percentage of monoclinic phase were evaluated. Regarding surface treatment, the Grind group presented higher roughness and greater flexural strength compared to As Sintered group, while Grind + Polish showed intermediate roughness and flexural strength similar to Grind group. Aging had little effect on roughness, but yielded a significant reduction in flexural strength. Tetragonal to monoclinic phase transformation was observed in all groups, caused by both mechanical stresses (grinding and polishing) and LTD, which was similarly induced by the traditional autoclave method, as well as the thermocycling method The use of diamond burs to grind zirconia surface may result in deleterious effects on the surface quality of monolithic zirconia restorations, yet has a potential toughening effect by phase transformation. However, when zirconia is exposed to LTD, regardless of the surface treatment, degradation of the surface quality and strength are observed.

20.
Braz. oral res. (Online) ; 34: e105, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132706

RESUMO

Abstract The aim of this research was to evaluate the influence of MDP (10-methacryloyloxydecyl dihydrogen phosphate) concentration and application mode of experimental adhesives on microshear bond strength (μSBS) to dentin after storage in distilled water at 37°C for 24h and 6 months. Five experimental adhesives were prepared with: CQ, DABE, BHT, ethanol, HEMA, TEGDMA, Bis-EMA, UDMA, and Bis-GMA. Concentrations of 0 wt%, 3 wt%, 9 wt%, 12 wt% or 15 wt% of MDP were added to their composition. The adhesives were applied to flat dentin surfaces in etch-and-rinse or self-etching modes. Cylindrical molds filled with light-cured composite resin were placed above the dentin. The specimens were stored in distilled water at 37oC for 24h or 6 months and submitted to μSBS testing. The adhesives were also submitted to pH analysis. The data were analyzed by one-way ANOVA, three-way ANOVA and Tukey's test (α = 5%). All the adhesives used in the etch-and-rinse mode showed significantly higher bond strength than the adhesives applied in the self-etching approach. The 9 wt% adhesive showed the highest bond strength values, and 3 wt% was most stable after storage. A strong negative correlation between MDP concentration and pH was observed. It was concluded that the formulations with low concentrations of MDP (up to 9 wt%) showed better results for bond strength and bond strength degradation over time.


Assuntos
Colagem Dentária , Resistência à Tração , Teste de Materiais , Adesividade , Adesivos Dentinários , Resinas Compostas , Cimentos de Resina , Cimentos Dentários , Dentina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...